Milk Concentrate Heater

PROBLEM

An overseas client required two large milk concentrate heaters to heat from 4 deg C to 75 deg C but had serious space limitations in a new building.  The viscous product and the installation requirements offered a challenge.

SOLUTION

Hipex manufactured two vertically orientated Mixchanger systems with support stands to hold the tubes in position through three levels of a multi-storey building.  Access to the "working" sections of the heat exchanger (top and bottom) was then easy as it was at a level where operators did not have to endanger themselves.  Hipex also used their compact hot water set to provide the heating medium for the process.  This fitted easily into the spare space in the building.